Tested with opsi 4.0.1
requiredWinstVersion >= 4.10.8.6
For 64 Bit
By Thomas_H 2011/10/27 12:58
Steps:
To avoid collisions between 32 and 64 Bit-Office you better have separate opsi-packages for each version.
[Initial] LogLevel=9 ; Log Errors in Logfile but don't abort: ExitOnError=false ; Show syntax errors in the script: ScriptErrorMessages=on ; Dont trace step by step through the script: TraceMode=off ; let started programs run in front of the winst window StayOnTop=false [Actions] requiredWinstVersion >= "4.10.8.6" DefVar $MsiId32$ DefVar $UninstallProgram32$ DefVar $MsiId64$ DefVar $UninstallProgram64$ DefVar $LogDir$ DefVar $ProductId$ DefVar $MinimumSpace$ DefVar $InstallDir32$ DefVar $InstallDir64$ DefVar $ExitCode$ DefVar $LicenseRequired$ DefVar $LicenseKey$ DefVar $LicensePool$ DefVar $INST_SystemType$ DefVar $INST_architecture$ DefVar $Version$ DefVar $Inst_Cmd32$ DefVar $Inst_Cmd64$ DefVar $Inst_Prg$ DefVar $Uninst_Cmd$ DefVar $Uninst_Prg$ Set $INST_SystemType$ = GetSystemType set $INST_architecture$ = GetProductProperty("install_architecture","system specific") Set $LogDir$ = "%SystemDrive%\tmp" ; ---------------------------------------------------------------- ; - Please edit the following values - ; ---------------------------------------------------------------- ;$ProductId$ should be the name of the product in opsi ; therefore please: only lower letters, no umlauts, ; no white space use '-' as a seperator Set $ProductId$ = "Microsoft-Office (64 Bit)" Set $Version$ = "2011" Set $MinimumSpace$ = "30 MB" ; the path were we find the product after the installation Set $InstallDir32$ = "%ProgramFiles32Dir%\Microsoft Office" Set $InstallDir64$ = "%ProgramFiles64Dir%\Microsoft Office" Set $LicenseRequired$ = "false" Set $LicensePool$ = "p_" + $ProductId$ Set $Inst_Prg$ = "setup.exe" Set $Inst_Cmd64$ = '/config' Set $Uninst_Cmd$ = "" Set $Uninst_Prg$ = "" ; ---------------------------------------------------------------- if not(HasMinimumSpace ("%SystemDrive%", $MinimumSpace$)) LogError "Not enough space on %SystemDrive%, " + $MinimumSpace$ + " on drive %SystemDrive% needed for " + $ProductId$ isFatalError ; Stop process and set installation status to failed else comment "Show product picture" ShowBitmap "%ScriptPath%\" + $ProductId$ + ".jpg" $ProductId$ if $LicenseRequired$ = "true" comment "Licensing required, reserve license and get license key" Sub_get_licensekey endif comment "Installiere Microsoft Office 2010 (64 Bit)..." if (($INST_SystemType$ = "x86 System") and ($INST_architecture$ = "system specific")) or ($INST_architecture$ = "both") or ($INST_architecture$ = "32 only") Message "Dieses Produkt ist nur fuer 64 Bit OS!" comment "Fatal: for 64 Bit OS only!" isFatalError Sub_check_exitcode endif if ($INST_SystemType$ = "64 Bit System") and (($INST_architecture$ = "system specific") or ($INST_architecture$ = "both") or ($INST_architecture$ = "64 only")) Message "Installiere " + $ProductId$ + ". Das kann etwas laenger dauern, bitte Geduld..." comment "Start setup program" Winbatch_install_64 Files_delete_64 Sub_check_exitcode endif endif [Winbatch_install_64] ; Choose one of the following examples as basis for your installation ; You can use $LicenseKey$ var to pass a license key to the installer ; ; === Nullsoft Scriptable Install System ================================================================ %ScriptPath%\$Inst_Prg$ $Inst_Cmd64$ "%Scriptpath%\ProPlus.WW\config.xml" [Files_delete_64] ; Example of recursively copying some files into the installation directory: ; delete /s "$InstallDir64$\*.*" [Sub_check_exitcode] comment "Test for installation success via exit code" set $ExitCode$ = getLastExitCode if ($ExitCode$ = "0") comment "Looks good: setup program gives exitcode zero" else comment "Setup program gives a exitcode unequal zero: " + $ExitCode$ if ($ExitCode$ = "1605") comment "ERROR_UNKNOWN_PRODUCT 1605 This action is only valid for products that are currently installed." comment "Uninstall of a not installed product failed - no problem" else if ($ExitCode$ = "1641") comment "looks good: setup program gives exitcode 1641" comment "ERROR_SUCCESS_REBOOT_INITIATED 1641 The installer has initiated a restart. This message is indicative of a success." else if ($ExitCode$ = "3010") comment "looks good: setup program gives exitcode 3010" comment "ERROR_SUCCESS_REBOOT_REQUIRED 3010 A restart is required to complete the install. This message is indicative of a success." else logError "Fatal: Setup program gives an unknown exitcode unequal zero: " + $ExitCode$ isFatalError endif endif endif endif
[Initial] LogLevel=9 ; Log Errors in Logfile but don't abort: ExitOnError=false ; Show syntax errors in the script: ScriptErrorMessages=on ; Dont trace step by step through the script: TraceMode=off ; let started programs run in front of the winst window StayOnTop=false [Actions] requiredWinstVersion >= "4.10.8.6" DefVar $MsiId32$ DefVar $UninstallProgram32$ DefVar $MsiId64$ DefVar $UninstallProgram64$ DefVar $LogDir$ DefVar $ExitCode$ DefVar $ProductId$ DefVar $InstallDir32$ DefVar $InstallDir64$ DefVar $LicenseRequired$ DefVar $LicensePool$ DefVar $INST_SystemType$ DefVar $INST_architecture$ DefVar $Uninst_Cmd$ DefVar $Uninst_Prg$ Set $INST_SystemType$ = GetSystemType set $INST_architecture$ = GetProductProperty("install_architecture","system specific") Set $LogDir$ = "%SystemDrive%\tmp" ; ---------------------------------------------------------------- ; - Please edit the following values - ; ---------------------------------------------------------------- Set $ProductId$ = "Microsoft Office (64 Bit)" Set $InstallDir32$ = "%ProgramFiles32Dir%\Microsoft Office" Set $InstallDir64$ = "%ProgramFiles64Dir%\Microsoft Office" Set $LicenseRequired$ = "false" Set $LicensePool$ = "p_" + $ProductId$ Set $Uninst_Prg$ = "setup.exe" Set $Uninst_Cmd$ = " /uninstall ProPlus /config " ; ---------------------------------------------------------------- comment "Show product picture" ShowBitmap "%ScriptPath%\" + $ProductId$ + ".jpg" $ProductId$ Message "Deinstalliere " + $ProductId$ + ". Bitte etwas Geduld..." if FileExists($InstallDir64$+"\"+$Uninst_Prg$) Set $Uninst_Prg$ = $InstallDir64$+"\"+$Uninst_Prg$ comment "Start uninstall sub section" Sub "%ScriptPath%\delsub.ins" endif if FileExists("%ScriptPath%\"+$Uninst_Prg$) Set $Uninst_Prg$ = "%ScriptPath%\"+$Uninst_Prg$ comment "Start uninstall sub section" Sub "%ScriptPath%\delsub.ins" endif if $LicenseRequired$ = "true" comment "Licensing required, free license used" Sub_free_license endif ExitWindows /reboot [Sub_free_license] comment "License management is enabled and will be used" comment "Trying to free license used for the product" DefVar $result$ Set $result$ = FreeLicense($LicensePool$) ; If there is an assignment of a license pool to the product, it is possible to use ; Set $result$ = FreeLicense("", $ProductId$) ; ; If there is an assignment of a license pool to a windows software id, it is possible to use ; DefVar $WindowsSoftwareId$ ; $WindowsSoftwareId$ = "..." ; set $result$ = FreeLicense("", "", $WindowsSoftwareId$)
if (($INST_SystemType$ = "x86 System") and ($INST_architecture$ = "system specific")) or ($INST_architecture$ = "both") or ($INST_architecture$ = "32 only") Message $ProductId$ + " ist nur fuer 64 Bit..." comment "Fatal: Nur fuer 32 Bit OS!" isFatalError endif if ($INST_SystemType$ = "64 Bit System") and (($INST_architecture$ = "system specific") or ($INST_architecture$ = "both") or ($INST_architecture$ = "64 only")) Message "Uninstalling " + $ProductId$ + " 64 Bit..." if FileExists($Uninst_Prg$) comment "Uninstall program found, starting uninstall" Winbatch_uninstall_64 comment "Removing "+$InstallDir64$ ; Files_uninstall_64 sub_check_exitcode endif endif [Winbatch_uninstall_64] ; Choose one of the following examples as basis for program uninstall ; ; === Nullsoft Scriptable Install System ================================================================ ; "$UninstallProgram64$" /S ; ; === Inno Setup ======================================================================================== ; "$UninstallProgram64$" /silent /norestart "$Uninst_Prg$" $Uninst_Cmd$ "%ScriptPath%\ProPlus.WW\SilentUninstallConfig.xml" [Files_uninstall_64] ; Example for recursively deleting the installation directory (don't forget the trailing backslash): ; delete -sf "$InstallDir64$\" [Sub_check_exitcode] comment "Test for installation success via exit code" set $ExitCode$ = getLastExitCode ; informations to exit codes see ; http://msdn.microsoft.com/en-us/library/aa372835(VS.85).aspx ; http://msdn.microsoft.com/en-us/library/aa368542.aspx if ($ExitCode$ = "0") comment "Looks good: setup program gives exitcode zero" else comment "Setup program gives a exitcode unequal zero: " + $ExitCode$ if ($ExitCode$ = "1605") comment "ERROR_UNKNOWN_PRODUCT 1605 This action is only valid for products that are currently installed." comment "Uninstall of a not installed product failed - no problem" else if ($ExitCode$ = "1641") comment "looks good: setup program gives exitcode 1641" comment "ERROR_SUCCESS_REBOOT_INITIATED 1641 The installer has initiated a restart. This message is indicative of a success." else if ($ExitCode$ = "3010") comment "looks good: setup program gives exitcode 3010" comment "ERROR_SUCCESS_REBOOT_REQUIRED 3010 A restart is required to complete the install. This message is indicative of a success." else logError "Fatal: Setup program gives an unknown exitcode unequal zero: " + $ExitCode$ isFatalError endif endif endif endif
<Configuration Product="ProPlus"> <Display Level="basic" CompletionNotice="No" SuppressModal="Yes" AcceptEula="Yes" NoCancel="Yes" /> --> <Setting Id="SETUP_REBOOT" Value="Never" /> --> </Configuration>
You'll have to change some informations in the config.xml. This config.xml will install Word, Excel, Powerpoint and Outlook as local installed applications. MS-Access will installed if needed, also all other components, which are dispensable (in my humble opinion). This config.xml is for the unpatient boss in the company… :))
<Configuration Product="ProPlus"> <Display Level="basic" CompletionNotice="No" SuppressModal="Yes" AcceptEula="Yes" NoCancel="Yes" /> --> <!-- <Logging Type="standard" Path="%temp%" Template="Microsoft Office Professional Plus Setup(*).txt" /> --> <USERNAME Value="MyOrganisation" /> --> <COMPANYNAME Value="MyCompany" /> --> <PIDKEY Value="MyRegKey_MyRegKey" /> <AddLanguage Id="match" ShellTransform="yes"/> <!-- <AddLanguage Id="en-us" /> --> <!-- <AddLanguage Id="fr-fr" /> --> <!-- <AddLanguage Id="de-de" /> --> <!-- <AddLanguage Id="es-es" /> --> <!-- <INSTALLLOCATION Value="%programfiles%\Microsoft Office" /> --> <!-- <LIS CACHEACTION="CacheOnly" /> --> <!-- <LIS SOURCELIST="\\server1\share\Office;\\server2\share\Office" /> --> <!-- <DistributionPoint Location="\\server\share\Office" /> --> <!-- <OptionState Id="OptionID" State="absent" Children="force" /> --> <!-- <Setting Id="SETUP_REBOOT" Value="IfNeeded" /> --> <!-- <Command Path="%windir%\system32\msiexec.exe" Args="/i \\server\share\my.msi" QuietArg="/q" ChainPosition="after" Execute="install" /> --> </Configuration>